Spirometer SpirOx PRO
110mm thermal printer built-in can print out a clear clinical report predicted value measured value
Measurement methods:
Flow velocity detection: Screen type pneumotachograph flow sensor
Capacity detection: flow integration
Patient Data:
Patient informa- tion input | Patient ID | ID No.: XXXXXX | ID No.: XXXXXX | |
Gender | Gender: | Gender: | ||
Age | Age: | Age: | Years old | |
Height | Height: | Height: | cm | |
Weight | Weight: | Weight: | kg | |
Race | Race: | Race: | ||
Temperature | Temperature: | Temperature: | ℃ | |
Humidity | Humidity: | Humidity: | % | |
Atmosphere | Atmosphere: | Atmosphere: | mmHg |
Measuring range
Capacity range: 0L ~ 9L
F low velocity range: 0 ~ 14L / s
Measurement accuracy
Capacity: 0L ~ 1.6L (± 50ml)
6L ~ 9L (± 3%)
Flow rate: 5% or 0.2L / s
Respiratory rate: 4 / 20 ~ / min (± 1 / min)
20 / 60 / min (error: ± 5%)
Measuring time limit and degree
VC: 50s per time, measuring 3 times
FVC: 25s per time, measuring 3 times
MVV: 12 seconds per time, measuring 3 times
PARAMETER DESCRIPTION | DISPLAY | UNIT | ||
VC Test | Vital capacity,Maximum inspiration volume or Maximum exhalation volume | VC | VC | L |
Tidal volume | TV | TV | L | |
Expiratory reserved volume | ERV | ERV | L | |
Inspiratory reserved volume | IRV | IRV | L | |
Inspiratory capacity | IC | IC | L | |
FVC Test | Forced vital capacity | FVC | FVC | L |
Forced expiratory volume at 0.5sec | FEV0.5 | FEV0.5 | L | |
Forced expiratory volume at 1sec | FEV1.0 | FEV1.0 | L | |
Forced expiratory volume at 3sec | FEV3.0 | FEV3.0 | L | |
Forced expiratory volume1sec / Forced vital capacity | FEV1.0/G | FEV1.0/G | % | |
Forced expiratory volume1sec / vital capacity | FEV1.0%T | FEV1.0%T | % | |
Forced expiratory volume at 3sec / Forced vital capacity | FEV3.0%G | FEV3.0%G | % | |
Forced expiratory volume at 3sec / vital capacity | FEV3.0%T | FEV3.0%T | % | |
Extrapolated volume | Vext | Vext | L | |
Expiratory time | EX Time | EX Time | s | |
Maximal mid-expiratory flow | MMF | MMF | L/s | |
Peak expiratory flow | PEF | PEF | L/s | |
Mid(forced)-expiratory flow at 75% | MEF75 | MEF75 | L/s | |
Mid(forced)-expiratory flow at 50% | MEF50 | MEF50 | L/s | |
Mid(forced)-expiratory flow at 25% | MEF25 | MEF25 | L/s | |
Forced inspiratory vital capacity | FIVC | FIVC | L | |
Forced inspiratory volume at 0.5sec | FIV0.5 | FIV0.5 | L | |
Forced inspiratory volume at 1.0sec | FIV1.0 | FIV1.0 | L | |
Ratio of FIV1.0divided by FIVC | FIV1.0/FVC | FIV1.0/FVC | % | |
Ratio of FIV1.0divided by FVC | FIV1.0/FIVC | FIV1.0/FIVC | % | |
Peak inspiratory flow | PIF | PIF | L/s | |
Inspiratory flow at 50% | MIF50% | MIF50% | L/s | |
MVV Test | Maximum voluntary ventilation | MVV | MVV | L/min |
Respiration rate | RR | RR | /min | |
Tidal volume | TV | TV | L |
Display (LCD): 320 * 240 dot-matrix
printer: 110mm thermal printer
Data: 10 integral records
Other Note
Power: A.C. 100~220V 50/60Hz
The type of security: I Class B type
Transport and storage note
Ambient temperature range:-20°C ~ 55°C;
Relative humidity range: ≤ 93%;
Atmosphere pressure range: 500hPa ~ 1060hPa;
Working note
Surrounding temperature range: 10°C ~ +40°C;
Relative humidity range: 30% to 75%;
Atmosphere pressure range: 700hPa ~ 1060hPa;
Options:
SpioSoft PC Software for data transfer (Options)